{"product_id":"dr-choukroun-s-ocean™-prf-processing-cassette","title":"Dr. Choukroun’s Ocean™ PRF Processing Cassette","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eDr. Choukroun’s Ocean™ PRF Processing Cassette \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eDr. Choukroun’s Ocean™ PRF Processing Cassette is a dedicated chairside press box workstation designed for the controlled processing of A-PRF™ clots and S-PRF™ plasma. Engineered to standardize PRF preparation, it enables clinicians to efficiently produce A-PRF™ membranes, plugs, ponchos, and S-PRF™ sticky bone within a single organized system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eBeyond instrument storage, the PRF Ocean™ functions as a structured PRF processing platform. It supports PRF handling in both liquid form (S-PRF™) and solid clot form (A-PRF™), allowing precise manipulation, compression, and combination of autologous components during regenerative procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eThe integrated layout allows secure positioning of PRF tubes, organized staging of surgical instruments, uniform compression of A-PRF™ clots into membranes, controlled formation of plugs and ponchos, and predictable mixing of S-PRF™ with particulate graft material to produce cohesive sticky bone. The result is a streamlined, reproducible workflow that enhances procedural efficiency and biologic control in implant and grafting cases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003ePRF Ocean™ Cassette Component Overview\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e1- PRF Processing Tray\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003ePrimary working surface for A-PRF™ and S-PRF™ preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e1A. A-PRF™ Press Tray\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003eDesigned to compress A-PRF™ clots into uniform membranes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e1B. S-PRF™ Sticky Bone Compartment\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003eDedicated mixing chamber for combining particulate graft material with S-PRF™ plasma and exudate to form sticky bone\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e1C. A-PRF™ Plug Forming Cylinders\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003eFour cylindrical chambers for shaping A-PRF™ clots into plugs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e1D. PRF Plug Piston\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003eA weighted compression cylinder used to create pressure during A-PRF™ plug formation in section 1C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e2.- PRF Ocean™ Cassette Housing\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003cbr\u003eEncases the processing tray, allows tubes to be stored during processing, and houses PRF instruments for sterilization.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e2A. Integrated Tube Holders\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eTube holders are built into the cassette body, eliminating the need for an external tube holder.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e2B. Hand Instrument Storage Inserts\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eSilicon inserts are integrated into the cassette, which allows instruments such as graft packers or tweezers to be stored when not in use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e2C. Scissor Storing Clip\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eA scissor-holding clip is integrated into the lid of the cassette, which allows a scissor to be stored in the open position during sterilization.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eHow to Produce S-PRF™ Sticky Bone Using the PRF Ocean™\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eCentrifugation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eCentrifuge the green and red tubes according to the protocol sheets provided under Dr. Choukroun’s guidelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"2\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eTube Placement\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eAfter centrifugation, place both green and red tubes into Section 2A, the designated tube holders within the cassette. Allow the red tubes to remain upright with caps removed for a minimum of five minutes to complete coagulation before clot retrieval.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"3\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003ePrepare the Graft Base\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eDuring the coagulation period, dispense the selected particulate grafting material into Section 1B. Irrigate S-PRF™ plasma from the green tubes into the particulate and gently blend to initiate hydration.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"4\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eClot Processing\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eOnce coagulated, remove each A-PRF™ clot from the red tubes using sterile tweezers. Excise the red blood cell fraction from the base of each clot with surgical scissors to isolate the fibrin portion.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"5\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eMembrane Compression\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eRemove the press tray from Section 1A and place the A-PRF™ clots within the compartment. Reposition the press tray to apply uniform compression. The calibrated weight of the tray is sufficient to form membranes. If thinner membranes or accelerated processing is desired, position the PRF piston 1D over the press tray to increase applied pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"6\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eExudate Collection\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eCompression will generate plasma exudate. Aspirate this exudate using a sterile syringe.\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"7\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eFinal Sticky Bone Formation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eTransfer the collected exudate into Section 1B and incorporate it into the mixture of particulate graft and S-PRF™ plasma. Using a sterile instrument, blend thoroughly until a cohesive, moldable sticky bone consistency is achieved.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eOnce prepared, the sticky bone may be shaped to the desired dimensions and applied clinically for bone grafting procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eHow to Produce A-PRF™ Membranes, Ponchos, and Plugs Using the PRF Ocean™\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eA-PRF™ Membrane Preparation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eCentrifuge the red tubes according to the established A-PRF™ protocol.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eRemove the red caps and allow the tubes to remain upright for approximately five minutes to complete coagulation. Tubes may be stored in Section 2A during this period.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman';\"\u003eRemove each clot using sterile tweezers. Trim the red blood cell layer from the base of the clot with surgical scissors.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eTo form membranes, place the processed clots into Section 1A with the press tray removed. Reposition the press tray to apply uniform compression. The tray’s calibrated weight forms consistent membranes. If additional compression is required, position PRF piston 1D over the tray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eFollowing compression, membranes may be used immediately. If temporary storage is required, they may remain in Section 1A with the press tray removed. Pressed A-PRF™ membranes remain clinically usable for up to two hours after preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eA-PRF™ Poncho Fabrication\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eAfter membrane formation, position the membrane on top of the press tray in Section 1A. Using the integrated slit guide, create a central incision. This modification produces a poncho configuration suitable for placement around healing abutments or other prosthetic components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eA-PRF™\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003e \u003cb\u003ePlug Fabrication\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eAfter clot retrieval and removal of the red blood cell fraction, place each clot into one of the four cylindrical chambers in Section 1C. Position the PRF piston 1D over the selected chamber to apply vertical compression. Leave the clot in the plug cylinder with the piston pressing the clot for a minimum of five minutes to achieve proper plug formation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dr. Choukroun","offers":[{"title":"Default Title","offer_id":48491417764057,"sku":"PRF-OCEAN","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/9947\/3716\/files\/PRF-OceanDigitalOpen.jpg?v=1775501674","url":"https:\/\/www.bonegrafting.com\/products\/dr-choukroun-s-ocean%e2%84%a2-prf-processing-cassette","provider":"Avtec Surgical","version":"1.0","type":"link"}